본문
| Model | BS-AHIDC | 
|---|---|
| Used | Connecting HID(high intensity discharge) head lamp in vehicle with HID AHLS (Auto Headlamp Leveling System) | 
| Structure | ① Conductor ② Insulation ③ Taping ④ Shield ⑤ Jacket | 
Securing visual range by auto-controlling the intensity of illumination and the glancing angle to improve driving safety
Description
- Silicone rubber composite cable with excellent heat resistance and flexibility
 - Excellent for internal wiring of lamps and lighting equipment
 
Rating
- Temperature range : -60℃~200℃
 - Voltage : 300V/ 600V
 - Passing grade test for fire retardant, mechanical strength, and electrical characteristics according to UL standard
 
Property
- Excellent excess moisture, UV ultraviolet resistance, and ozone resistance for both high and low temperature environments
 - Easy to connect devices in narrow and high temperatures with great flexibility
 - Through multiple cladding structural design, shock resistance are excellent
 
C-UL Certification Approved
- File No. : E131290
 - Reference : UL 758, 1581
 
| Style No. | Rating | AWG No. | Insulation Thickness (mm) | |
|---|---|---|---|---|
| Volt.(V) | Temp.(℃) | |||
| 3977 | 300 | 200 | 0.05~250SQ | 0.38 | 
| 3978 | 600 | 200 | 0.05~250SQ | 0.76 | 
![]()